You are here: Home > Circuit Breakers > Square D / Telemecanique Circuit Breakers > HJA
Sort By:
Page of 1
HJA36125 HJA36125

BRAND NEW SURPLUS IN BOX SQUARE D I-LINE CIRCUIT BREAKER 3POLE 125AMP 480VOLT

Our Price: $1,368.86
HJA36150 HJA36150

SQD SQUARE D 150A 3P I-LINE 600V CIRCUIT BREAKER

Our Price: $1,368.86
HJA36060 HJA36060

NEW SURPLUS IN BOX

SQUARE D MOLDED CASE CIRCUIT BREAKER

• 240/480/600 Vac At 50/60 Hz, 480 Vac Star/277 Vac At 50/60 Hz, 600 Vac Star/347 Vac At 50/60 Hz (Ul/Csa/Nom)
• 240/415 Vac At 50/60 Hz (Iec)
• 60 Ampere
• 3 Pole
• Interrupting Rating 100 Kiloampere At 240 Vac, 65 Kiloampere At 480 Vac Star/277 Vac Or 480 Vac, 25 Ampere At 600 Vac Star/347 Vac Or 600 Vac (Ul/Csa/Nom)
• 100 Kiloampere At 240 Vac, 65 Kiloampere At 415 Vac (Iec)
• Trip Setting 800 To 1450 Ampere
• Application Power Distribution
• Used On Class 612 I-Line[R] Panelboard/Switchboard
• Approval Ul, Csa
• Hj Model
• Frame Type H
• Size 4.12 Inch W X 4.36 Inch D X 6.4 Inch H
• Tripping Method Thermal Magnetic
• Terminal Wire Size 14 To 3/0 Awg

Our Price: $499.99
HJA36015 (NSPPO) HJA36015 (NSPPO)

SQUARE D MOLDED CASE CIRCUIT BREAKER 15AMP 3POLE 600VOLT

Our Price: $499.99
HJA36020 (NSPPO) HJA36020 (NSPPO)

SQUARE D MOLDED CASE CIRCUIT BREAKER 20AMP 3POLE 600VOLT

Our Price: $499.99
HJA36080 (NSPPO) HJA36080 (NSPPO)

SQUARE D MOLDED CASE CIRCUIT BREAKER 80AMP 3POLE 600VOLT

Our Price: $499.99
HJA260506 HJA260506

NEW SURPLUS IN BOX

SQUARE D I-LINE CIRCUIT BREAKER

  • 240/480/600 Vac At 50/60 Hz, 480 Vac Star/277 Vac At 50/60 Hz, 600 Vac Star/347 Vac At 50/60 Hz (ul/csa/nom)
  • 240/415 Vac At 50/60 Hz (iec)
  • 50 Ampere
  • 2 Pole
  • Interrupting Rating 100 Kiloampere At 240 Vac, 65 Kiloampere At 480 Vac Star/277 Vac Or 480 Vac, 25 Ampere At 600 Vac Star/347 Vac Or 600 Vac (ul/csa/nom)
  • 100 Kiloampere At 240 Vac, 65 Kiloampere At 415 Vac (iec)
  • Trip Setting 400 To 850 Ampere
  • Application Power Distribution
  • Used On Class 612 I-Line[r] Panelboard/switchboard
  • Approval Ul, Csa
  • Hj Model
  • Frame Type H
  • Size 2.74 Inch W X 4.36 Inch D X 6.4 Inch H
  • Phase Connection 6
  • Tripping Method Thermal Magnetic
  • Terminal Wire Size 14 To 3/0 Awg
  • Our Price: $499.99
    HJA260201 HJA260201

    NEW SURPLUS IN BOX

    SQUARE D CIRCUIT BREAKER 240/480/600 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 600 VAC STAR/347 VAC AT 50/60 HZ (UL/CSA/NOM); 220/240/380/415/500/525 VAC (IEC 947-2); 20 AMPERE; 2 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC OR 480 VAC STAR/277 VAC, 25 AMPERE AT 600 VAC OR 600 VAC STAR/347 VAC (UL/CSA/NOM); 100 KILOAMPERE AT 220/240 VAC, 65 KILOAMPERE AT 380/415 VAC, 25 KILOAMPERE AT 500/525 VAC (IEC 947-2); TRIP SETTING 350 TO 750 AMPERE; APPLICATION DISTRIBUTION; USED ON CLASS 612 I-LINE[R] PANELBOARD; APPROVAL CE; HJ MODEL; FRAME TYPE H; TRIPPING METHOD THERMAL MAGNETIC; PHASE CONNECTION AB

    Our Price: $499.99
    HJA260202 HJA260202

    NEW SURPLUS IN BOX

    SQUARE D I-LINE CIRCUIT BREAKER 240/480/600 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 600 VAC STAR/347 VAC AT 50/60 HZ (UL/CSA/NOM); 220/240/380/415/500/525 VAC (IEC 947-2); 20 AMPERE; 2 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC OR 480 VAC STAR/277 VAC, 25 AMPERE AT 600 VAC OR 600 VAC STAR/347 VAC (UL/CSA/NOM); 100 KILOAMPERE AT 220/240 VAC, 65 KILOAMPERE AT 380/415 VAC, 25 KILOAMPERE AT 500/525 VAC (IEC 947-2); TRIP SETTING 350 TO 750 AMPERE; APPLICATION DISTRIBUTION; USED ON CLASS 612 I-LINE[R] PANELBOARD; APPROVAL CE; HJ MODEL; FRAME TYPE H; TRIPPING METHOD THERMAL MAGNETIC; PHASE CONNECTION AC

    Our Price: $499.99
    HJA260204 HJA260204

    NEW SURPLUS IN BOX

    SQUARE D I-LINE CIRCUIT BREAKER 240/480/600 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 600 VAC STAR/347 VAC AT 50/60 HZ (UL/CSA/NOM); 220/240/380/415/500/525 VAC (IEC 947-2); 20 AMPERE; 2 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC OR 480 VAC STAR/277 VAC, 25 AMPERE AT 600 VAC OR 600 VAC STAR/347 VAC (UL/CSA/NOM); 100 KILOAMPERE AT 220/240 VAC, 65 KILOAMPERE AT 380/415 VAC, 25 KILOAMPERE AT 500/525 VAC (IEC 947-2); TRIP SETTING 350 TO 750 AMPERE; APPLICATION DISTRIBUTION; USED ON CLASS 612 I-LINE[R] PANELBOARD; APPROVAL CE; HJ MODEL; FRAME TYPE H; TRIPPING METHOD THERMAL MAGNETIC; PHASE CONNECTION BC

    Our Price: $499.99
    HJA260501 HJA260501

    NEW SURPLUS IN BOX

    SQUARE D I-LINE CIRCUIT BREAKER 240/480/600 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 600 VAC STAR/347 VAC AT 50/60 HZ (UL/CSA/NOM); 220/240/380/415/500/525 VAC (IEC 947-2); 50 AMPERE; 2 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC OR 480 VAC STAR/277 VAC, 25 AMPERE AT 600 VAC OR 600 VAC STAR/347 VAC (UL/CSA/NOM); 100 KILOAMPERE AT 220/240 VAC, 65 KILOAMPERE AT 380/415 VAC, 25 KILOAMPERE AT 500/525 VAC (IEC 947-2); TRIP SETTING 400 TO 850 AMPERE; APPLICATION DISTRIBUTION; USED ON CLASS 612 I-LINE[R] PANELBOARD; APPROVAL CE; HJ MODEL; FRAME TYPE H; TRIPPING METHOD THERMAL MAGNETIC; PHASE CONNECTION AB

    Our Price: $499.99
    HJA260206 HJA260206

    NEW SURPLUS IN BOX

    SQUARE D I-LINE CIRCUIT BREAKER 240/480/600 VAC AT 50/60 HZ, 480 VAC STAR/277 VAC AT 50/60 HZ, 600 VAC STAR/347 VAC AT 50/60 HZ (UL/CSA/NOM); 220/240/380/415/500/525 VAC (IEC); 125/250 VDC; 20 AMPERE; 2 POLE; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC STAR/277 VAC OR 480 VAC, 25 KILOAMPERE AT 600 VAC STAR/347 VAC OR 600 VAC (UL/CSA/NOM); 100 KILOAMPERE AT 220/240 VAC, 65 KILOAMPERE AT 380/415 VAC, 25 KILOAMPERE AT 500/525 VAC (IEC); 20 KILOAMPERE AT 125/250 VDC; TRIP SETTING 350 TO 750 AMPERE; APPLICATION DISTRIBUTION; USED ON I-LINE[R] PANELBOARD/SWITCHBOARD; H MODEL; TRIPPING METHOD THERMAL MAGNETIC; PHASE CONNECTION CB

    Our Price: $499.99
    HJA36100 W3 SQD HJ150 HJA36100 W3 SQD HJ150

    NEW SURPLUS

    SQD SQUARE D 600V 3P 100A I-LINE CIRCUIT BREAKER HJ150

    Our Price: $607.43
    HJA36040-S SQD W3 HJA36040-S SQD W3

    NEW SURPLUS

    SQUARE D I-LINE CIRCUIT BREAKER 40A 600 V 3 POLE

    Our Price: $299.99