You are here: Home > VFD AC Variable Frequency Drive > TECO-WESTINGHOUSE - Braking Unit

Braking Unit

JUVPLV 230V, 460V Series

HP: N/A

Features


  • Robust Power Transistor for High Duty Cycles
  • Fault Contact for Heatsink Overheat Condition
  • Hinged Cover for Easy Installation and Service
  • Units Can be Paralleled for High HP Braking
  • HP Rated For Easy Application: 20, 30, 40, 60HP
  • Power Charge Indicator Lamp
  • -10 to 40°C Ambient Temperature Range
  • NEMA Enclosure
 

230V 3-Phase
AC DRIVE
HP RATING
BRAKING TRANSISTOR
BRAKING RESISTOR
MODEL
NUMBER
QTY
USED
MODEL NUMBER
QTY
USED
RESISTANCE
ENCLOSURE
DIMENSIONS
BRAKING
TORQUE %
DUTY
CYCLE %
OHMS
WATTS
1
X
­
DBR-019
1
200
70
12"L X 5"W X 5"D
125
10
2
X
­
DBR-027
1
100
260
12"L X 5"W X 5"D
125
10
3
X
­
DBR-035
1
70
260
12"L X 5"W X 5"D
120
10
5
X
­
DBR-043
1
40
390
12"L X 5"W X 5"D
125
10
7.5
X
­
DBR-051
1
30
520
12"L X 7"W X 5"D
115
10
10
X
­
DBR-060
1
20
780
12"L X 7"W X 5"D
125
10
15
X
­
DBR-078
1
13.6
2400
19"L X 10"W X 5"D
125
10
20
X
­
DBR-086
1
10
3000
19"L X 13"W X 5"D
125
10
25
JUPLV-60
1
DBR-094
1
8
4800
26.5"L X 10"W X 5"D
125
10
30
JUPLV-60
1
DBR-108
1
6.8
4800
26.5"L X 10"W X 5"D
125
10
40
JUPLV-40
2
DBR-086
2
10
3000
19"L X 13"W X 5"D
125
10
50
JUPLV-40
2
DBR-086
2
10
3000
19"L X 13"W X 5"D
100
10
60
JUPLV-60
2
DBR-094
2
8
4800
26.5"L X 10"W X 5"D
120
10
75
JUPLV-60
2
DBR-094
2
8
4800
26.5"L X 10"W X 5"D
100
10
100
JUPLV-60
3
DBR-094
3
8
4800
26.5"L X 10"W X 5"D
110
10

460V 3-Phase

AC DRIVE
HP RATING

BRAKING TRANSISTOR

BRAKING RESISTOR

MODEL
NUMBER

QTY
USED

MODEL NUMBER

QTY
USED

RESISTANCE

ENCLOSURE
DIMENSIONS

BRAKING
TORQUE %

DUTY
CYCLE %

OHMS

WATTS

1

X

­

DBR-116

1

750

70

12"L X 5"W X 5"D

130

10

2

X

­

DBR-124

1

400

260

12"L X 5"W X 5"D

125

10

3

X

­

DBR-132

1

250

260

12"L X 5"W X 5"D

135

10

5

X

­

DBR-141

1

150

390

12"L X 5"W X 5"D

135

10

7

X

­

DBR-159

1

100

520

12"L X 7"W X 5"D

135

10

10

X

­

DBR-167

1

75

780

12"L X 7"W X 5"D

130

10

15

X

­

DBR-175

1

50

1040

12"L X 10"W X 5"D

135

10

20

X

­

DBR-183

1

40

1560

12"L X 13"W X 5"D

125

10

25

JUVPHV-40

1

DBR-191

1

32

4800

26.5"L X 13"W X 5"D

125

10

30

JUVPHV-40

1

DBR-205

1

27.2

4800

26.5"L X 13"W X 5"D

125

10

40

JUVPHV-40

1

DBR-213

1

20

6000

26.5"L X 13"W X 5"D

125

10

50

JUVPHV-60

1

DBR-221

1

16

9600

28"L X 10"W X 10"D

125

10

60

JUVPHV-60

1

DBR-230

1

13.6

9600

28"L X 10"W X 10"D

125

10

75

JUVPHV-40

2

DBR-213

2

20

6000

26.5"L X 13"W X 5"D

135

10

100

JUVPHV-60

2

DBR-230

2

13.6

9600

28"L X 10"W X 10"D

145

10

125

JUVPHV-40

3

DBR-213

3

20

6000

26.5"L X 13"W X 5"D

125

10

150

JUVPHV-40

3

DBR-213

3

20

6000

26.5"L X 13"W X 5"D

100

10

175-200

JUVPHV-60

4

DBR-230

4

13.6

9600

28"L X 10"W X 10"D

140

10

X = Transistor built-in for all MA7200, PA7300, and N3 Drives at these ratings.
For braking applications above 100 HP at 230V or above 200 HP at 460V, please consult customer service.
 
Note:
All brake resistor units include thermal overload switches.